Monte Carlo evaluation of kerma in an HDR brachytherapy bunker

2004

In recent years, the use of high dose rate (HDR) after-loader machines has greatly increased due to the shift from traditional Cs-137/Ir-192 low dose rate (LDR) to HDR brachytherapy. The method used to calculate the required concrete and, where appropriate, lead shielding in the door is based on analytical methods provided by documents published by the ICRP, the IAEA and the NCRP. The purpose of this study is to perform a more realistic kerma evaluation at the entrance maze door of an HDR bunker using the Monte Carlo code GEANT4. The Monte Carlo results were validated experimentally. The spectrum at the maze entrance door, obtained with Monte Carlo, has an average energy of about 110 keV, m…

Internationalitymedicine.medical_treatmentNuclear engineeringBrachytherapyPhysics::Medical PhysicsMonte Carlo methodBrachytherapyRadiation DosageRisk AssessmentKermaLead shieldingRadiation ProtectionRadiation MonitoringRisk FactorsOccupational ExposuremedicineScattering RadiationComputer SimulationHospital Design and ConstructionRadiology Nuclear Medicine and imagingMonte carlo evaluationLow dose rateSimulationPhysicsModels StatisticalRadiology Department HospitalRadiological and Ultrasound TechnologyMonte carlo codeDose rateMonte Carlo MethodPhysics in Medicine and Biology